Multi-Functional Pyrolysis System

Multi-Functional Pyrolysis System

The Multi-Functional Pyrolysis System consists of the Multi-Shot Pyrolyzer (EGA/PY-3030D) and its accessories. This system is able to rapidly characterize virtually any material.

 

 

sys conf py
Accessories
Consumables
Compatibility with various GCs
Operating environment of software
FAQ
Video tutorials

 

Auto-shot sampler tandem reactor selective sampler micro jet cryo trap metal capillary column vent free adapter

 

Multi-functional system and related products

Multi-Shot Pyrolyzer (EGA/PY-3030D)

 

py3030d

[Features]
1) Significant improvement in cycle time of analyses
The new development of a lower heat capacity ceramic heater enhances more rapid heating and cooling rate as well as broader pyrolysis temperature ranging from room temperature up to 1050°C.
2) Guaranteed reliability and reproducibility
Inertness of flow path, elution of high boiling compounds as well as reproducibility of pyrograms and thermograms are guaranteed (Detector: MS)
3) Analysis of any sample form
Any sample forms can be chemically characterized by multiple, thermal techniques:
(1) Evolved Gas Analysis
(2) Thermal Desorption Analysis
(3) Single-Shot Analysis
(4) Double-Shot Analysis
(5) Heart-cut EGA-GC/MS Analysis
(6) Reactive Pyrolysis Analysis
(7) UV Pyrolysis Analysis
(8) High Pressure Reactive Analysis
Catalog FAQ

 

 

NEW F-Search System Ver. 3.5 – search software with polymer and additive libraries

 

fs-1

The system consists of F-Search software and four types of libraries listed below. The F-Search system allows you to rapidly search the libraries for polymers and additives. The number of additives stored in the ADD-MS library have been increased in the latest Ver. 3.5.

 

1) EGA-MS polymer library : 700 polymers stored
2) PyGC-MS polymer library : 700 polymers stored
3) Pyrolyzate-MS library : 165 polymers stored
4) ADD-MS library : 494 additives stored (136 newly added)

pdf Catalog

pdf Polymer list

pdf Additive list

faq FAQ

Download Trial Version

 

Single-Shot Pyrolyzer (PY-3030S)

py3030s

Dedicated for pyrolysis.

pdf Catalog
faqFAQ

 

Auto-Shot Sampler (AS-1020E)

as1020e
A 48 position auto sampler compatible with both the single and multi shot pyrolyzers used for pyrolysis, TD or EGA.

pdf Catalog
faqFAQ

 

Micro-UV Irradiator (UV-1047Xe)

uv1045e
The effects of “weather” upon exposure to the photo / thermal oxidative degradation process can quickly be evaluated.

pdf Catalog

 

NEW Multi-Sample UV Irradiator (UV-1048E)

UV-1048E

An option for Micro UV Irradiator (UV-1047Xe). It can simultaneously irradiate a maximum of 18 polymer samples in accelerated deterioration tests.

pdf Catalog

 

MicroJet Cryo-Trap (MJT-1035E)

Cryo-traps low boiling compounds at the front of capillary column by cooling a spot of the column to -196°C using Liq. N2. The universal design allows it to work with most sample introduction devices.

pdf Catalog

 

 

 

 

Selective Sampler (SS-1010E)

ss1010e

Any set of EGA thermal zones can be heart-cut and the components introduced into a capillary column or vented.

pdf Catalog
faqFAQ

 

 

Carrier Gas Selector (CGS-1050Ex)

cgs1050ex

A device for the quick and easy switching of carrier gases. It is useful for the analysis of atmospheric oxidation and environmental pollutants.

pdf Catalog
faqFAQ

 

NEW F-Search System Ver. 3.5 (search engine & libraries)
(PY-1110E-161)

micro_reactor
Characterizes polymeric materials and additives from pyrograms and EGA thermograms.
pdf Catalog
pdf Polymer List
pdf Additive List
faqFAQ
Trial Version

 

On-line Micro Reaction Sampler (PY1-1050)

micro_reactor
Seal sample and reagent in a glass capsule and after the high pressure, high temperature reaction inside EGA/PY-3030D, the capsule is shattered and the reaction products are introduced on-line into a GC separation column.

pdf Catalog

 

Micro TD Sampler (PY1-1060)

TD_Sampler

Volatile organic compounds adsorbed on Tenax, activated carbon or other sorbents can be concentrated and analyzed using the EGA/PY-3030D pyrolyzer.

pdf Catalog

 

Vent-free GC/MS Adapter

vfadaptor

Allows switching a separation column and EGA tube without venting the MS system.

pdf Catalog

 

NEW Micro Sample Collector

mcsorber
This is a very useful tool used to collect a small amount of liquids or paste-like materials that are difficult to pick up using tweezers.

pdf Catalog

 

Magic Chemisorber

mcsorber
Solid phase extraction element bounded thick polydimethylsiloxane onto outer surface of a titanium tube.

pdf Catalog

 

Micro-puncher

Micro puncher

Convenient tool for sampling film-like materials.

pdf Catalog

 

Sampling Tool Kit 01

Sampling Tool Kit 01

A set of various types of tools to sample solid polymers for Pyrolysis-GC/MS.

pdf Catalog

 

NEW Sampling Tool Kit 02

Sampling Tool Kit 02

Ten tools have been newly added to the existing Sampling Tool Kit 01. By selecting the right tool for the form of sample, you can collect samples easily.

pdf Catalog

 

NEW Phthalate-free Quartz Wool

Quartz_wool
Ultra clean quartz wool and ready to use without any further treatment. Contains extremely low level of seven phthalates guaranteed by test certificate.

pdf Catalog

 

NEW Polymer Coated Cup G

Polymer_Coated_Cup

Auto-Shot Sampler can be used in analysis of low boiling phthalates using thermal desorption GC/MS. Simply add phthalates standard solution and ready to use.

pdf Catalog

 

 

Eco-cup

ss-cup
Stainless steel; the entire surface has been coated by quartz thin film.

pdf Selection guide

 

Eco-cup G series

gl-cup

G series sample cups are made of pyrex glass. Because the cups are made of glass, the sample position, sample color change, residues, and contamination can be observed.

pdf Catalog

 

 

Auto-Rx Disc

AutoRx_illust

Allows the use of the Auto-Shot Sampler when using reactive pyrolysis-GC with TMAH.

pdf Catalog

 

Parts and Consumables

supplies

Parts and Consumables

pdf Catalog

faqFAQ